INSTALLATION TIPS
The system can be operated freestanding,
lying horizontally or vertically.
Water pressure at the filter system
inlet must not exceed 116 psi (8 bar). A
pressure reducer valve must be installed
on the water supply side of the filter
system if the inlet pressure exceeds
116 psi (8 bar).
Shutoff valve must be installed upstream
of the filter.
Refer to Installation, Operation &
Maintenance Manual for cartridge flushing
and start-up.
OPERATION TIPS
Change Claris Ultra Cartridge when its
precalculated water volume has been
reached or at least once per year.
Change cartridge when capacity
is reached.
Always flush the filter cartridge at time of
installation and cartridge change.
Do not use hardness test strips to check for
hardness reduction. Please use a titration
kit to check for hardness reduction.
SIZING
Service Flow Rate: 1.0 gpm (3.7 Lpm)
Rated Capacity:
4,358 gallons (16,500 L) for Espresso
5,283 gallons (20,000 L) for Coffee/OCS
This capacity is based on influent water
hardness of 180 ppm with standard bypass
settings.
SPECIFICATIONS
Service Flow Rate
1.0 gpm (3.7 Lpm)
Rated Capacity
4,358 gallons (16,500 L) for Espresso
5,283 gallons (20,000 L) for Coffee/OCS
This capacity is based on influent water
hardness of 180 ppm with standard
bypass settings.
Pressure Requirements
29 - 116 psi (2 - 8 bar), non-shock
Temperature Limits
39 - 86°F (4 - 30°C)
Overall Dimensions
18.56” H x 6.89” dia (47.1 x 17.5 cm)
Electrical Connection
None required